OH2 Pump

Usages: 

  • Oil and Gas
  • Petrochemical
  • Power Plant

 

 


Download product catalog

Description

Design:

  • Horizontal, radial split with single or double volute
  • Single-stage, single-suction
  • Centerline-mounted
  • Single bearing housing to absorb all forces acting on shaft
  • Mounted on base plate with flexible coupling to driver
  • Casing design with heating or cooling jacket available
  • Volute casing with feet on centerline
  • Mechanical seals if any design

Features:

  • Coupling with spacer for rapid dismantling and assembly
  • Fully (usually) interchangeably modular elements
  • Minimizing spare parts

Additional information

Type of bearing

Ball and Rolling element bearings

Casing partition

Radially split

Drive frequency

50 / 60 Hz

Type of drive

Electric motor / Diesel Engine

Drive voltage

Low voltage

No. of Impeller entries

Single entry

Type of coupling

Direct – Flexible –Spacer coupling

Type of lubrication

Type of lubrication Grease / Oil

Max. permissible fluid temperature

Based on Material

Nozzle position

End /Top

Pull-out design

Pull-out design Yes

Pump set location

Dry installed

Shaft material

Table H-1 of API610

Suction characteristics

Non-priming

Type of casing

Volute casing

Type of Impeller

Radial, Closed, Multi-vane Impeller

Maximum Head

300 m

Minimum Head

9 m

Installation position

Horizontal

Shaft seal type

Mechanical / Soft Packing seal

Main applications

Industry and process Engineering, Energy

Casing material

Table H-1 of API610

Maximum discharge-side pressure

150 bar

Maximum drive rating

220 kW

Type of installation

Stationary

Temperature

-20 to +450 0C

Minimum flow rate

2 m3/h

Maximum speed of rotation

Maximum speed of rotation